aboutsummaryrefslogtreecommitdiff
path: root/Bindings/power/supply/battery.yaml
diff options
context:
space:
mode:
authorEmmanuel Vadot <manu@FreeBSD.org>2021-01-14 15:25:07 +0000
committerEmmanuel Vadot <manu@FreeBSD.org>2021-01-14 15:25:07 +0000
commit5ee353c36d3c9c7f63df7c7671875e73fba70958 (patch)
tree77f0dc489fc4baaf2bab03da6d182a7339bc1297 /Bindings/power/supply/battery.yaml
parent2554fe8f89383d8dedd834b46a9f616a277f8af4 (diff)
downloadsrc-5ee353c36d3c9c7f63df7c7671875e73fba70958.tar.gz
src-5ee353c36d3c9c7f63df7c7671875e73fba70958.zip
Import device tree files from Linux 5.9vendor/device-tree/5.9
Diffstat (limited to 'Bindings/power/supply/battery.yaml')
-rw-r--r--Bindings/power/supply/battery.yaml144
1 files changed, 144 insertions, 0 deletions
diff --git a/Bindings/power/supply/battery.yaml b/Bindings/power/supply/battery.yaml
new file mode 100644
index 000000000000..932b736ce5c0
--- /dev/null
+++ b/Bindings/power/supply/battery.yaml
@@ -0,0 +1,144 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/power/supply/battery.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Battery Characteristics
+
+maintainers:
+ - Sebastian Reichel <sre@kernel.org>
+
+description: |
+ The devicetree battery node provides static battery characteristics.
+ In smart batteries, these are typically stored in non-volatile memory
+ on a fuel gauge chip. The battery node should be used where there is
+ no appropriate non-volatile memory, or it is unprogrammed/incorrect.
+
+ Upstream dts files should not include battery nodes, unless the battery
+ represented cannot easily be replaced in the system by one of a
+ different type. This prevents unpredictable, potentially harmful,
+ behavior should a replacement that changes the battery type occur
+ without a corresponding update to the dtb.
+
+ Battery properties are named, where possible, for the corresponding elements
+ in enum power_supply_property, defined in include/linux/power_supply.h
+
+ Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
+ The phandle's property should be named "monitored-battery".
+
+properties:
+ compatible:
+ const: simple-battery
+
+ over-voltage-threshold-microvolt:
+ description: battery over-voltage limit
+
+ re-charge-voltage-microvolt:
+ description: limit to automatically start charging again
+
+ voltage-min-design-microvolt:
+ description: drained battery voltage
+
+ voltage-max-design-microvolt:
+ description: fully charged battery voltage
+
+ energy-full-design-microwatt-hours:
+ description: battery design energy
+
+ charge-full-design-microamp-hours:
+ description: battery design capacity
+
+ trickle-charge-current-microamp:
+ description: current for trickle-charge phase
+
+ precharge-current-microamp:
+ description: current for pre-charge phase
+
+ precharge-upper-limit-microvolt:
+ description: limit when to change to constant charging
+
+ charge-term-current-microamp:
+ description: current for charge termination phase
+
+ constant-charge-current-max-microamp:
+ description: maximum constant input current
+
+ constant-charge-voltage-max-microvolt:
+ description: maximum constant input voltage
+
+ factory-internal-resistance-micro-ohms:
+ description: battery factory internal resistance
+
+ resistance-temp-table:
+ description: |
+ An array providing the temperature in degree Celsius
+ and corresponding battery internal resistance percent, which is used to
+ look up the resistance percent according to current temperature to get an
+ accurate batterty internal resistance in different temperatures.
+
+ ocv-capacity-celsius:
+ description: |
+ An array containing the temperature in degree Celsius,
+ for each of the battery capacity lookup table.
+
+required:
+ - compatible
+
+patternProperties:
+ '^ocv-capacity-table-[0-9]+$':
+ $ref: /schemas/types.yaml#/definitions/uint32-matrix
+ description: |
+ An array providing the open circuit voltage (OCV)
+ of the battery and corresponding battery capacity percent, which is used
+ to look up battery capacity according to current OCV value. And the open
+ circuit voltage unit is microvolt.
+ maxItems: 100
+ items:
+ items:
+ - description: open circuit voltage (OCV) in microvolts
+ - description: battery capacity percent
+ maximum: 100
+
+additionalProperties: false
+
+examples:
+ - |
+ power {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ battery: battery {
+ compatible = "simple-battery";
+ over-voltage-threshold-microvolt = <4500000>;
+ re-charge-voltage-microvolt = <250000>;
+ voltage-min-design-microvolt = <3200000>;
+ voltage-max-design-microvolt = <4200000>;
+ energy-full-design-microwatt-hours = <5290000>;
+ charge-full-design-microamp-hours = <1430000>;
+ precharge-current-microamp = <256000>;
+ precharge-upper-limit-microvolt = <2500000>;
+ charge-term-current-microamp = <128000>;
+ constant-charge-current-max-microamp = <900000>;
+ constant-charge-voltage-max-microvolt = <4200000>;
+ factory-internal-resistance-micro-ohms = <250000>;
+ ocv-capacity-celsius = <(-10) 0 10>;
+ /* table for -10 degree Celsius */
+ ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
+ /* table for 0 degree Celsius */
+ ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>;
+ /* table for 10 degree Celsius */
+ ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>;
+ resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
+ };
+
+ charger@11 {
+ reg = <0x11>;
+ monitored-battery = <&battery>;
+ };
+
+ fuel-gauge@22 {
+ reg = <0x22>;
+ monitored-battery = <&battery>;
+ };
+ };