aboutsummaryrefslogtreecommitdiff
path: root/contrib/netbsd-tests/fs/nfs/nfsservice/rpcbind/check_bound.c
diff options
context:
space:
mode:
Diffstat (limited to 'contrib/netbsd-tests/fs/nfs/nfsservice/rpcbind/check_bound.c')
-rw-r--r--contrib/netbsd-tests/fs/nfs/nfsservice/rpcbind/check_bound.c231
1 files changed, 231 insertions, 0 deletions
diff --git a/contrib/netbsd-tests/fs/nfs/nfsservice/rpcbind/check_bound.c b/contrib/netbsd-tests/fs/nfs/nfsservice/rpcbind/check_bound.c
new file mode 100644
index 000000000000..2ea7c31d16ca
--- /dev/null
+++ b/contrib/netbsd-tests/fs/nfs/nfsservice/rpcbind/check_bound.c
@@ -0,0 +1,231 @@
+/* $NetBSD: check_bound.c,v 1.1 2010/07/26 15:53:00 pooka Exp $ */
+
+/*
+ * Sun RPC is a product of Sun Microsystems, Inc. and is provided for
+ * unrestricted use provided that this legend is included on all tape
+ * media and as a part of the software program in whole or part. Users
+ * may copy or modify Sun RPC without charge, but are not authorized
+ * to license or distribute it to anyone else except as part of a product or
+ * program developed by the user.
+ *
+ * SUN RPC IS PROVIDED AS IS WITH NO WARRANTIES OF ANY KIND INCLUDING THE
+ * WARRANTIES OF DESIGN, MERCHANTIBILITY AND FITNESS FOR A PARTICULAR
+ * PURPOSE, OR ARISING FROM A COURSE OF DEALING, USAGE OR TRADE PRACTICE.
+ *
+ * Sun RPC is provided with no support and without any obligation on the
+ * part of Sun Microsystems, Inc. to assist in its use, correction,
+ * modification or enhancement.
+ *
+ * SUN MICROSYSTEMS, INC. SHALL HAVE NO LIABILITY WITH RESPECT TO THE
+ * INFRINGEMENT OF COPYRIGHTS, TRADE SECRETS OR ANY PATENTS BY SUN RPC
+ * OR ANY PART THEREOF.
+ *
+ * In no event will Sun Microsystems, Inc. be liable for any lost revenue
+ * or profits or other special, indirect and consequential damages, even if
+ * Sun has been advised of the possibility of such damages.
+ *
+ * Sun Microsystems, Inc.
+ * 2550 Garcia Avenue
+ * Mountain View, California 94043
+ */
+/*
+ * Copyright (c) 1986 - 1991 by Sun Microsystems, Inc.
+ */
+
+/* #ident "@(#)check_bound.c 1.15 93/07/05 SMI" */
+
+#if 0
+#ifndef lint
+static char sccsid[] = "@(#)check_bound.c 1.11 89/04/21 Copyr 1989 Sun Micro";
+#endif
+#endif
+
+/*
+ * check_bound.c
+ * Checks to see whether the program is still bound to the
+ * claimed address and returns the univeral merged address
+ *
+ */
+
+#include <sys/types.h>
+#include <sys/socket.h>
+#include <rpc/rpc.h>
+#include <stdio.h>
+#include <netconfig.h>
+#include <syslog.h>
+#include <string.h>
+#include <unistd.h>
+#include <stdlib.h>
+
+#include <rump/rump.h>
+#include <rump/rump_syscalls.h>
+
+#include "rpcbind.h"
+
+struct fdlist {
+ int fd;
+ struct netconfig *nconf;
+ struct fdlist *next;
+ int check_binding;
+};
+
+static struct fdlist *fdhead; /* Link list of the check fd's */
+static struct fdlist *fdtail;
+static const char emptystring[] = "";
+
+static bool_t check_bound(struct fdlist *, const char *uaddr);
+
+/*
+ * Returns 1 if the given address is bound for the given addr & transport
+ * For all error cases, we assume that the address is bound
+ * Returns 0 for success.
+ */
+static bool_t
+check_bound(struct fdlist *fdl, const char *uaddr)
+{
+ int fd;
+ struct netbuf *na;
+ int ans;
+
+ if (fdl->check_binding == FALSE)
+ return (TRUE);
+
+ na = uaddr2taddr(fdl->nconf, uaddr);
+ if (!na)
+ return (TRUE); /* punt, should never happen */
+
+ fd = __rpc_nconf2fd(fdl->nconf);
+ if (fd < 0) {
+ free(na);
+ return (TRUE);
+ }
+
+ ans = bind(fd, (struct sockaddr *)na->buf, na->len);
+
+ rump_sys_close(fd);
+ free(na);
+
+ return (ans == 0 ? FALSE : TRUE);
+}
+
+int
+add_bndlist(struct netconfig *nconf, struct netbuf *baddr)
+{
+ struct fdlist *fdl;
+ struct netconfig *newnconf;
+
+ newnconf = getnetconfigent(nconf->nc_netid);
+ if (newnconf == NULL)
+ return (-1);
+ fdl = (struct fdlist *)malloc((u_int)sizeof (struct fdlist));
+ if (fdl == NULL) {
+ freenetconfigent(newnconf);
+ syslog(LOG_ERR, "no memory!");
+ return (-1);
+ }
+ fdl->nconf = newnconf;
+ fdl->next = NULL;
+ if (fdhead == NULL) {
+ fdhead = fdl;
+ fdtail = fdl;
+ } else {
+ fdtail->next = fdl;
+ fdtail = fdl;
+ }
+ /* XXX no bound checking for now */
+ fdl->check_binding = FALSE;
+
+ return 0;
+}
+
+bool_t
+is_bound(const char *netid, const char *uaddr)
+{
+ struct fdlist *fdl;
+
+ for (fdl = fdhead; fdl; fdl = fdl->next)
+ if (strcmp(fdl->nconf->nc_netid, netid) == 0)
+ break;
+ if (fdl == NULL)
+ return (TRUE);
+ return (check_bound(fdl, uaddr));
+}
+
+/*
+ * Returns NULL if there was some system error.
+ * Returns "" if the address was not bound, i.e the server crashed.
+ * Returns the merged address otherwise.
+ */
+char *
+mergeaddr(SVCXPRT *xprt, char *netid, char *uaddr, char *saddr)
+{
+ struct fdlist *fdl;
+ char *c_uaddr, *s_uaddr, *m_uaddr, *allocated_uaddr = NULL;
+
+ for (fdl = fdhead; fdl; fdl = fdl->next)
+ if (strcmp(fdl->nconf->nc_netid, netid) == 0)
+ break;
+ if (fdl == NULL)
+ return (NULL);
+ if (check_bound(fdl, uaddr) == FALSE)
+ /* that server died */
+ return strdup(emptystring);
+ /*
+ * If saddr is not NULL, the remote client may have included the
+ * address by which it contacted us. Use that for the "client" uaddr,
+ * otherwise use the info from the SVCXPRT.
+ */
+ if (saddr != NULL) {
+ c_uaddr = saddr;
+ } else {
+ c_uaddr = taddr2uaddr(fdl->nconf, svc_getrpccaller(xprt));
+ if (c_uaddr == NULL) {
+ syslog(LOG_ERR, "taddr2uaddr failed for %s",
+ fdl->nconf->nc_netid);
+ return (NULL);
+ }
+ allocated_uaddr = c_uaddr;
+ }
+
+#ifdef RPCBIND_DEBUG
+ if (debugging) {
+ if (saddr == NULL) {
+ fprintf(stderr, "mergeaddr: client uaddr = %s\n",
+ c_uaddr);
+ } else {
+ fprintf(stderr, "mergeaddr: contact uaddr = %s\n",
+ c_uaddr);
+ }
+ }
+#endif
+ s_uaddr = uaddr;
+ /*
+ * This is all we should need for IP 4 and 6
+ */
+ m_uaddr = addrmerge(svc_getrpccaller(xprt), s_uaddr, c_uaddr, netid);
+#ifdef RPCBIND_DEBUG
+ if (debugging)
+ fprintf(stderr, "mergeaddr: uaddr = %s, merged uaddr = %s\n",
+ uaddr, m_uaddr);
+#endif
+ if (allocated_uaddr != NULL)
+ free(allocated_uaddr);
+ return (m_uaddr);
+}
+
+/*
+ * Returns a netconf structure from its internal list. This
+ * structure should not be freed.
+ */
+struct netconfig *
+rpcbind_get_conf(const char *netid)
+{
+ struct fdlist *fdl;
+
+ for (fdl = fdhead; fdl; fdl = fdl->next)
+ if (strcmp(fdl->nconf->nc_netid, netid) == 0)
+ break;
+ if (fdl == NULL)
+ return (NULL);
+ return (fdl->nconf);
+}