hwpmc: do not register RAPL when the unit register reads as zero
An energy status unit of zero means one joule per raw tick, which no part
reports; it is what a hypervisor returns for an MSR it does not implement.
Both energy rows are scaled by that field, so the class would be
registered with counters that read zero forever.
Refuse it, as the class is already refused when no energy MSR responds.