aboutsummaryrefslogtreecommitdiff
path: root/sys/contrib/openzfs/man/man8/zpool-events.8
diff options
context:
space:
mode:
Diffstat (limited to 'sys/contrib/openzfs/man/man8/zpool-events.8')
-rw-r--r--sys/contrib/openzfs/man/man8/zpool-events.883
1 files changed, 65 insertions, 18 deletions
diff --git a/sys/contrib/openzfs/man/man8/zpool-events.8 b/sys/contrib/openzfs/man/man8/zpool-events.8
index 2d32dce2bb65..3753139bdfe7 100644
--- a/sys/contrib/openzfs/man/man8/zpool-events.8
+++ b/sys/contrib/openzfs/man/man8/zpool-events.8
@@ -113,17 +113,19 @@ See
for more details on the
.Sy zfs_vdev_direct_write_verify
module parameter.
-.It Sy config
+.It Sy config_sync
Issued every time a vdev change have been done to the pool.
.It Sy zpool
Issued when a pool cannot be imported.
-.It Sy zpool.destroy
+.It Sy pool_create
+Issued when a pool is created.
+.It Sy pool_destroy
Issued when a pool is destroyed.
-.It Sy zpool.export
+.It Sy pool_export
Issued when a pool is exported.
-.It Sy zpool.import
+.It Sy pool_import
Issued when a pool is imported.
-.It Sy zpool.reguid
+.It Sy pool_reguid
Issued when a REGUID (new unique identifier for the pool have been regenerated)
have been detected.
.It Sy vdev.unknown
@@ -150,21 +152,31 @@ event.
Issued when the label is OK but invalid.
.It Sy vdev.bad_ashift
Issued when the ashift alignment requirement has increased.
-.It Sy vdev.remove
+.It Sy vdev_remove
Issued when a vdev is detached from a mirror (or a spare detached from a
vdev where it have been used to replace a failed drive - only works if
the original drive have been re-added).
-.It Sy vdev.clear
+.It Sy vdev_remove_aux
+Issued when an auxiliary vdev is removed.
+.It Sy vdev_remove_dev
+Issued when a specific device is removed from a vdev.
+.It Sy vdev_clear
Issued when clearing device errors in a pool.
Such as running
.Nm zpool Cm clear
on a device in the pool.
-.It Sy vdev.check
+.It Sy vdev_check
Issued when a check to see if a given vdev could be opened is started.
-.It Sy vdev.spare
+.It Sy vdev_spare
Issued when a spare have kicked in to replace a failed device.
-.It Sy vdev.autoexpand
+.It Sy vdev_autoexpand
Issued when a vdev can be automatically expanded.
+.It Sy vdev_add
+Issued when a vdev is added to a pool.
+.It Sy vdev_attach
+Issued when a vdev is attached to a mirror or raidz vdev type.
+.It Sy vdev_online
+Issued when an offline vdev is brought online
.It Sy io_failure
Issued when there is an I/O failure in a vdev in the pool.
.It Sy probe_failure
@@ -175,21 +187,56 @@ have removed the device).
.It Sy log_replay
Issued when the intent log cannot be replayed.
The can occur in the case of a missing or damaged log device.
-.It Sy resilver.start
+.It Sy resilver_start
Issued when a resilver is started.
-.It Sy resilver.finish
+.It Sy resilver_finish
Issued when the running resilver have finished.
-.It Sy scrub.start
+.It Sy scrub_start
Issued when a scrub is started on a pool.
-.It Sy scrub.finish
+.It Sy scrub_finish
Issued when a pool has finished scrubbing.
-.It Sy scrub.abort
+.It Sy scrub_abort
Issued when a scrub is aborted on a pool.
-.It Sy scrub.resume
+.It Sy scrub_resume
Issued when a scrub is resumed on a pool.
-.It Sy scrub.paused
+.It Sy scrub_paused
Issued when a scrub is paused on a pool.
-.It Sy bootfs.vdev.attach
+.It Sy errorscrub_start
+Issued when a errorscrub is started on a pool.
+.It Sy errorscrub_finish
+Issued when a pool has finished errorscrubbing.
+.It Sy errorscrub_abort
+Issued when a errorscrub is aborted on a pool.
+.It Sy errorscrub_resume
+Issued when a errorscrub is resumed on a pool.
+.It Sy errorscrub_paused
+Issued when a errorscrub is paused on a pool.
+.It Sy trim_start
+Issued when a trim is started on a pool.
+.It Sy trim_finish
+Issued when a pool has finished trimbing.
+.It Sy trim_cancel
+Issued when a trim is canceled on a pool.
+.It Sy trim_resume
+Issued when a trim is resumed on a pool.
+.It Sy trim_suspend
+Issued when a trim is suspend on a pool.
+.It Sy authentication
+Issued when there is a decryption / authentication error.
+.It Sy config_cache_write
+Issued when the config cache file cannot be written.
+.It Sy bootfs_vdev_attach
+Issued when a vdev is attached to a root pool with the bootfs property set.
+.It Sy sitout
+Issued when a
+.Sy RAIDZ
+or
+.Sy DRAID
+vdev triggers the
+.Sy autosit
+logic.
+This logic detects when a disk in such a vdev is significantly slower than its
+peers, and sits them out temporarily to preserve the performance of the pool.
.El
.
.Sh PAYLOADS